Need Datasheets?
Click Here to visit our Datasheet Server (TDS, SDS, Fact Sheets, Selector Guides, etc)Maven EA 120HP is a toughened, 2:1 ratio mix, High-viscosity, industrial grade epoxy adhesive with a 2-hour extended work life. Once mixed, the two-component epoxy cures at room temperature to form a tough, amber-white, bondline which provides high peel resistance, high shear strengths, and high resistance to impact and vibration. The fully cured epoxy is resistant to a wide range of chemicals and solvents, and acts as an excellent electrical insulator.
Backup/Substitute Formulas:
TYPICAL APPLICATIONS
The high performance epoxy provides excellent bond strengths to a wide variety of plastics and metals. Ideal for general purpose industrial applications requiring extended work life for adjusting parts during assembly.
Typical application includes bonding piecesin aerospace applications. EA120HP bondsdissimilar materials including aluminum,steel, and other metals and a variety ofplastics. It is especially formulated for a 2:1mix ratio for use in side-by-side cartridges,or to be used by hand mixing, or use with Meter Mix Equipment. A handling cure is normally achieved at room temperature within 4 hours with a full cure at roomtemperature within 48 hours. To accelerate the final cure, or to quicken the handling simply elevate the temperature.
Data Sheets Page:
https://tools.perigeedirect.com/data-sheets/
Chemical / Solvent Resistance
Cured for 5 days at 22°C on steel with no induced gap, aged under conditions indicated and tested at 22°C.
Solvent Temp. % Initial Strength retained at
500h vs. 1000h
Air |
87°C |
- |
100 |
Motor Oil (10W-30) |
87°C |
125 |
120 |
Unleaded Gasoline |
87°C |
- |
105 |
Water/Glycol (50%/50%) |
87°C |
90 |
90 |
Salt/Fog ASTM B-117 |
22°C |
- |
45 |
95% Relative Humidity |
38°C |
- |
80 |
Condensing Humidity |
49°C |
- |
60 |
Water |
22°C |
- |
70 |
Acetone |
22°C |
- |
100 |
Isopropyl Alcohol |
22°C |
- |
110 |
Directions for use
1. For high strength structural bonds, removal of surface pollutants such as paint, oxide films, oils, dust, mold release agents and all other surface pollutants.
2. Use gloves to minimize skin contact. DO NOT use solvents for cleaning hands.
3. 2-Part Cartridges: To use simply insert the cartridge into the application gun and start the plunger into the cylinders using light pressure on the trigger. Next, remove the cartridge cap and expel a small amount of adhesive to be sure both sides are flowing evenly and freely. If automatic mixing of resin and hardener is desired, attach the mixing nozzle to the end of the cartridge and begin dispensing the adhesive. For hand mixing, expel the desired amount of the adhesive and mix thoroughly. Mix approximately 15 seconds after uniform color is obtained. Bulk Containers: Mix thoroughly by weight or volume in the proportions specified in Properties of Uncured Material section. Mix vigorously approximately 15 seconds after uniform color is obtained.
4. For maximum bond strength apply adhesive evenly to both surfaces to be joined.
5. Application to the substrates should be made within 60 minutes. Larger quantities and/or higher temperatures will reduce this working time.
6. Join the adhesive coated surfaces and allow to cure at 25°C (77°F) for 24 hours for high strength. Heat up to 93°C (200°F), will speed curing.
7. Keep parts from moving during cure. Contact pressure is necessary. Maximum shear strength is obtained with a 3-9 mil bond line.
8. Excess uncured adhesive can be cleaned up with ketone type solvents.
Storage
Product shall be ideally stored in a cool, dry location in unopened containers at a temperature between 8°C to 28°C (46°F to 82°F) unless otherwise labeled. Optimal storage is at the lower half of this temperature range. To prevent pollution of unused product, do not return any material to its original container. For further specific shelf life information, contact your local Technical Service Center.
Data Ranges
The data contained herein may be reported as a typical value and/or range. Values are based on actual test data and are verified on a periodic basis.
And especially if you are considering or comparing a few different formulas. Our datasheet server can help you download the necessary data to help u decide and keep your project going.